Basic Info.
Application
Laboratory Apparatus
Detection Method
Spectrophotometer
Advantage
High Resolution
Principle
Classic Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
RoHS, ISO9001, CE
Customized
Non-Customized
Wavelength Range
190nm-900nm
Spectral Bandwidth
0.1, 0.2, 0.4, 1.0 and 2.0nm
Accuracy of The Wavelength
±0.15nm
Receptivity of The Wavelength
≤0.04nm
Base Line Stability
≤0.002A/30min (Cu)
Characteristic Viscosity
0.02μg/Ml/1% (Cu)
Checking Limit
0.004μg/Ml (Cu)
Inflamer
All-Metal Titanium Burner
Atomizer
Effective Glass Atomizer
Size and Weight
700mm×550mm×450mm 75kg
Acetylene Air Burner
100mm
Product Description
BNAAS-B4530G Atomic Absorption SpectrophotometerFeatures:
1. Completely controlled by PC, can flflexibly select the flflame and graphite furnace atomizer (optional).
2. Integrated flfloated optical platform design can obviously improve the optical system shock resistance and keep stable though
use the optical signal for a long term.
3. Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condi
tion of the hollow cathode lamp.
4. Position adjusting: the best height of the flflame burner and can automatically set the front and rear positions.
5. Fully automated wavelength scanning and peak searching.
6. Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong
burner, leakage of the gas, under voltage of air and the abnormal flflameout.
7. Deuterium lamp and self-absorption background regulation
8. Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store
the analyzed result with the form of EXCEL and the testing method and the result can be randomly called.
9. Measuring method: flflame absorption method and emission method.
10. Result printing: parameter printing, data result printing and diagram printing
Advanced graphite furnace temperature controlling technology1.The bringing in of PID technology can effectively overcome
the inflfluence on the temperature rising process caused by the
voltage flfluctuation and the resistance change to make more
accurate controlling process. The combination of the
3ms/time fast sampling technique can make more accurate
and reliable testing data
2.The fast heating capacity can improve the flflexibility of the
elements further
3.Use the ordinary power source of 220V without need of
dynamic power of 380V
4.The maximum procedure heating capacity setting of 20
levels can make a more convenient and easier test of different
samples
5.Three grades adjustable gas flflow can accustom to more
application needs
6.Can timely alarm when the gas and water is stopped and
insufficient gas and water, can avoid the equipment damage
and measuring errorComplete automatic controlling system Selection of the element lamp
Up-down-front-rear adjustment of the lifter
Adjustment of the optical energy
Selection of the slit
Determination of wavelength scanning and peak searching
Selection of the atomizer
Setting of the background deduction method
Controlling of the gas flflow
Automatic flflaming and flflaming out
Setting of the graphite furnace testing methodSafe, reliable and convenient flflame system 1.EPC can control the flflow of Acetylene (C2H2) more accurate
ly and it is a kind of system which also can operate easily
2.Efficient atomization system enables a higher sensitivity
3.The whole operation system has a high security as the fire
safety system can alarm whenever the electricity is cut off,
abnormal flflame occurs, a lack of pressure happens or the
burner does not match well. And it will automatically turn off
the gas, prohibit tempering. Thus it keeps the operation people
and equipment from harm and damage.Multi-functional software workstation 1.A workstation that is supported WINDOWS 7
2.The rich menu brings great convenience to the use of
customer
3.Convenient conversion between different menus makes the
operation more easily
4.Various analytical correction methods provide the users
more choices
5.Basic default parameter settings enable even the beginners
can do the normal operation
6.Flexible storage, editing and printing methods give the user
largest supportSpecification:Wavelength range | 190 - 900nm |
Spectral bandwidth | 0.1, 0.2, 0.4, 1.0 and 2.0nm |
Accuracy of the wavelength | ±0.15nm |
Receptivity of the wavelength | ≤0.04nm |
Base line stability | ≤0.002A/30min (Cu) |
Characteristic viscosity | 0.02μg/ml/1% (Cu) |
Checking limit | 0.004μg/ml (Cu) |
Preciseness | 0.50% |
Grating | 1800 lines/mm |
Inflamer | All-metal titanium burner |
Atomizer | Effective glass atomizer |
Lamp stand | 8 |
D2 background correction ability | When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method |
Size and weight | 700mm×550mm×450mm 75Kg |
Power source | 220V±22V AC |
SAcetylene air burner | 100mm |
Ignition dynamic baseline drift | ≤0.006A/30min |
(Cu) Characteristic viscosity | ≤0.025μg/ml/1% |
Related standard deviation of the accuracy | ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml) |
Safety system | Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner. |
The highest temperature | 3000ºC |
The largest temperature rising speed | ≥2000ºC/S |
Characteristic quantity | Cd≤0.5×10-12g Cu≤0.5×10-11g |
Accuracy | Cu≤3% Cd≤3% |
Size and weight | 550mm×450mm×300mm 65Kg |
Safety system | Over current protection Low air pressure alarm / protection Low cooling water flow alarm/protection |
Power source and power | 220V±22V AC 7000W |
Please send inquiry>>
Address:
Rm 1101 building 1, No1428 Huanding Rd, Jianggan Dist., Hangzhou 310021, China
Business Type:
Trading Company
Business Range:
Furniture, Health & Medicine, Industrial Equipment & Components, Instruments & Meters, Tools & Hardware
Management System Certification:
ISO 9001
Company Introduction:
HANGZHOU BOYN INSTRUMENT Co., Ltd is one of the leading companies for providing you the widest range of laboratory equipment and educational apparatus and medical instruments from China.
BOYN′s products are widely applicable for university and college, hospital, pharmaceutical industry, ministry of environmental protection and scientific research institute etc. We assure the quality and durability of all our products, as each product is individually tested and inspected by our proficient technicians before dispatching the consignment.
We are ISO 9001: 2015 Certified company and All our products are designed and manufactured in accordance with ISO9001 / ISO13485 by dedicated and experienced R&D engineering team.